Product Description

Socomec's DIRIS A-40 is a panel-mounted power monitoring device (PMD). The meter offers a range of functions for measuring voltage, current, power, energy and quality. It also allows for the analysis of a single-phase or three-phase load.

Product Features:
  • CL0.2 accuracy
  • Autocorrect current transformer
  • Configuration wizard set-up
  • THD Measurement up to 63rd

Specification

Auxiliary Power Supply

Alternative Voltage

110/400 VAC or 120/300 VDC - Cat III

Frequency

50/60 Hz

Power Consumption

5VA AC / 1,5VA DC

Connection

Removable spring-cage terminal block, 2x 2 positions, 0.5 - 2.5 mm2 solid cable or 0.25 - 1.5 mm² stranded cable with end piece

Power and Energy Measurement

Accuracy

Active energy and active power

0.2 DIRIS A-40 class only

Class 0.5 with TE, TF or iTR sensors

Class 1 with TR sensors

Accuracy of reactive energy

Class 2 with TE, TR or TF sensors

Power Factor Measurement

Accuracy

Class 0.5 with TE, TF or iTR sensors

Class 1 with TR sensors

Voltage Measurement

Characteristics of the network measured

50-300VAC (Ph/N) - 87-520VAC (Ph/Ph) - CATIII

Frequency range

45 to 65Hz

Frequency accuracy

Class 0.02

Network type

Single-phase/ Two-phase / Two-phase with neutral / Three-phase / Three-phase with neutral

Measurement by voltage transformer

Primary: 400 000 VAC

Secondary: 60, 100, 110, 173, 190 VAC

Input consumption

≤0,1VA

Accuracy of voltage measurement

Class 0.2

Connection

Removable spring-cage terminal block,
4 positions, 0.5 - 2.5 mm² solid cable
or 0.25 - 1.5 mm² stranded cable with end piece

Current Measurement

Number of current inputs

3

Associated current sensors

Solid TE, split-core TR, flexible TF current sensors

Accuracy

0.2 DIRIS A-40 class only

Class 0.5 with TE, TF or iTR sensors

Class 1 with TR sensors

Connection

Specific Socomec cable with RJ12 connectors

Input Characteristics

Number

3

Type / Power supply

Optocoupler with internal (12 VDC ± 10%) or external (12-24 VDC ± 20%) polarisation

Input function

Logic status, status of circuit breaker, synchronization topography, multifluid pulse metering

Connection

Removable screw terminal block, 5 positions, stranded or solid 0.14 - 1.5 mm² cable

Output Characteristics

Number

2

Type

Optocoupler 30 Vd.c. max 20mA max - SELV

Output function

Command, energy pulse output, load sheeding, alarm

Connection

Removable screw terminal block, 4 positions, stranded or solid 0.14 - 1.5 mm² cable

Communication Characteristics

Link

RS485

Connection type

2 to 3 half duplex wires

Protocol

Modbus RTU

Baud rate

1200 to 115 200 baud

USB

Configuration of DIRIS A-40

Downloads

Ask an expert about the
Socomec DIRIS A-40 Multi-Function Modbus Meter (4825-0500)

Help & Advice

Knowledge Base

Knowledge Base

Our Knowledge Base section provides in-depth guides on metering related topics, and can aid you in the process of buying the right product.

Find out more
Subscribe to our newsletter

For exclusive promotions, discounts, news and more

Get exclusive offers, discounts and news straight to your inbox…

Sign up to our newsletter today

Subscribe Now

Our Products

addressarrow-leftcaret-downcaret-leftcaret-rightmenuorderpadlockpdf