Carlo Gavazzi's EM112 range of meters are suitable for billing applications for small loads (up to 100A) with two tariff options for users. Housed in 2-DIN module fashion, the meter's small and compact design makes it ideal for quick installation.

Product Features:
  • Class 1 (kWh) according to EN62053-21
  • Class B (kWh) according to EN50470-3
  • Accuracy ±0.5% RDG (current/voltage)
  • Energy parameters: kWh, kVARh (imported/exported); kWh + 2 tariffs
  • System parameters: kW, kVAr, V, A, PF, Hz, kW Demand, kW demand peak
  • Energy readout on display: 8 digit
  • Variable readout on display: 4 digit
  • MID Certified
  • Four Quadrant Measuring (Import/Export)
  • Self power supply
  • Modbus RS485 output

Specification

Rated Inputs

Current type

1-phase loads, direct
connection

Current rate

5(100)A

Nominal voltage

230VLN AC (AV0 option),
120 VLN (AV1 option)

Accuracy (@25°C ±5°C, R.H. ≤60%, 45 to 65 Hz)

AV1

Imin=0.25A
Ib: 5A
Imax: 100A
Un: 120VLN -30% +30%

AV0

Imin=0.25A
Ib: 5A
Imax:100A
Un: 230VLN -30% +20%

Active energy

Class 1 according to EN62053-21 and MID Annex MI-003 Class B (Class B (kWh) according to EN50470-3)

Reactive energy

Class 2 according to EN62053-23

Start-up current

40mA (AV0, AV1), positive or negative. Self-consumption is not measured.

Start-up voltage

84VLN (AV1), 161VLN (AV0)

Overloads

Current

Continuous: 100A @ 50Hz
For 500ms: 2Un

Voltage

Continuous: 1.2 Un
For 500ms: 2Un

General

Sampling rate

4096 samples/s @ 50Hz

Operating temperature

-25 to +65 °C, indoor, (R.H. from 0 to 90% noncondensing @ 40°C)

Storage temperature

-30°C to +80°C (R.H. < 90% noncondensing @ 40°C)

Overvoltage category

Cat. III

Temperature drifts

100ppm/°C

Standard

Safety: EN62052-11
Metrology: EN62053-21, EN50470-3

Approvals

CE, MID (PF option only)

Mechanical

Connections

Cable cross-section area: Measuring inputs: max. 25 mm², min. 5mm² with/without metallic cable ferrule; Max. screw tightening torque: 2.8 Nm
Other Terminals: 1.5 mm², Min./Max. screws tightening torque: 0.5 Nm

Dimensions (W x H x D)

35 x 63 x 90 mm (2 DIN module)

Material

Noryl, self-extinguishing:
UL 94 V-0

Sealing covers

Included

Mounting

DIN-rail

Protection degree

Front: IP51
Screw terminals (cable inputs):
IP20

Weight

Approx. 160 g (packing included)

Power Supply

Self power supply

AV0: 230VAC VL-N, -30% +20% 50/60Hz


AV1: 120VAC VL-N, -30% +30% 50/60Hz

Power consumption

≤ 1.0W, ≤ 8VA

Downloads

Ask an expert about the
Carlo Gavazzi EM112

Help & Advice

Knowledge Base

Knowledge Base

Our Knowledge Base section provides in-depth guides on metering related topics, and can aid you in the process of buying the right product.

Find out more
Subscribe to our newsletter

For exclusive promotions, discounts, news and more

Get exclusive offers, discounts and news straight to your inbox…

Sign up to our newsletter today

Subscribe Now

Our Products

addressarrow-leftcaret-downcaret-leftcaret-rightmenuorderpadlockpdf