The Smart X96-5 is a high accuracy multifunction power meter that is a traditional wired 1/5A current transformer operated meter. Configurable for 1p2w, 3p3w and 3p4w systems and hosting a vast range of measuring parameters such as Amps, Volts, Power, Power and Current Demand (Sliding and fix scale options), Power Factor, imported and exported kWh, Individual harmonics, Phase sequence and a phase summary page. It is one of the most user-friendly multifunction power meters in the market form installation to end client use.
It is typical in most installations that the current transformers are mounted on the left-hand side of the breaker so P1 is facing the correct way. However, it is also possible to mount the current transformer on the right-hand side with P2 facing the breaker. This is possible due to the meter having the option to reverse the flow to correct this type of application.
The SMART X96-5 requires mains voltage inputs and external current transformers in order to operate, it is self-supplied via a internal three phase transformer, this means if any of the phases fail the meter will remain powered and does not require an external auxiliary supply. The Smart X96-5 meter comes complete with RS485 Modbus RTU and dual pulsed outputs as standard.
Nominal Input Voltage | 100-276V AC (L-N) 173-480 AC (L-L) |
Max. Continuous Input Overload Voltage | 120% of nominal |
Max. Short Duration Input Voltage | 2x nominal voltage for 1 second |
Nominal Input Voltage Burden | < 0.2VA per phase |
Nominal Input Current | 1/5A |
Nominal Input Current Burden | <0.1VA |
Max. Continuous Input Overload Current | 120% of nominal |
Max. Short Duration Input Current | 20 x nominal current for 1 second |
Operating Range | Self powered (from any of the three phases) |
Supply Burden | <2W/10VA |
Voltage (V) | 0.5% of range maximum |
Current (A) | 0.5% of range maximum |
Frequency (Hz) | 0.2% of mid-frequency |
Power Factor (PF) | 1% of unity (0.01) |
Active Power (W) | 1.0% of range maximum |
Reactive Power (VAr) | 1.0% of range maximum |
Apparent Power (VA) | 1.0% of range maximum |
Active Energy (kWh) | Class 0.5S IEC62053-22
Class 1.0 IEC62053-21 |
Reactive Energy (kVArh) | 1.0% of range maximum to IEC 62053-24 |
THD | 2% to 63rd harmonic |
Operational Temperature | -25°C - +55°C |
Storage Temperature | -40°C - +70°C |
Relative Humidity | 0 to 95%, non condensing |
Shock | 30g in 3 planes |
Vibration | 10Hz to 50Hz, IEC 60068-2-6, 2g |
Dielectric Voltage | 4kV between voltage and current to earth |
Altitude | 3000m |
Warm-Up | 1 minute |
Pulsed Output Relay (Configurable) | Opto coupled, potential-free SPST-NO contact |
Contact Rating Current | 2-27ma at 27V DC |
Contact Rating Voltage | 5-27V DC |
Pulse Width | 60/100/200ms |
Pulse Rate of SO 1 | 0.01/0.1/1/10/100 kWh/kVArh |
Pulsed Output of SO 2 (Non-Configurable) | 3200IMP/kWh |
Communications | Modbus RTU (RS485) |
Type | 2-wire half duplex |
Baud Rate | 2400, 4800, 9600, 19200, 38400 |
Address | 1 to 247 |
Enclosure Style | DIN96 panel mount |
Dimensions | 96x96x62mm |
Panel Cut-Out | 92x92mm |
Panel Thickness | 1-2mm |
Protection Rating | IP51 (Indoor) |
Material | UL 94-V0 |
Weight | 340g |
Cable Size | 0.05mm-4mm stranded wire |
Terminals | Voltage: Shrouded screw-clamp, Current RJ12 |
Our Knowledge Base section provides in-depth guides on metering related topics, and can aid you in the process of buying the right product.
Find out moreOur in-house product experts are at hand to help you find the right products and solutions for your projects.
01423 340 000 Start live chatFor exclusive promotions, discounts, news and more
Get exclusive offers, discounts and news straight to your inbox…
Sign up to our newsletter today